As a precision instrument for observing the microscopic world of biological sections, cells, bacteria, and so on, the use method and precautions are very important for biological section manufacturers. The following is a brief overview of the use and precautions of biological microscopes shared by biological microtome manufacturers:
​Usage method
​Preparation stage: Place the microscope smoothly on the bench to ensure that the ambient light is appropriate. Take the microscope with both hands, holding the arm with one hand and the base with the other to avoid vibration.
​Installation and debugging: Install the eyepiece and objective, turn the converter to align the low-power objective with the light hole. Adjust the aperture and mirror for a clear and bright view.
​Place the specimen: Place the biological slice on the loading platform and fix it with the press clip to ensure that the specimen is facing the center of the light hole.

ada
​​​Adjust the focal length: Use a coarse parafocal spiral to slowly lower the tube until the objective is close to the specimen (avoid direct contact). Then turn the coarse quasi-focal spiral in the opposite direction, make the lens barrel slowly rise, and observe the change of the object in the eyepiece. When the image is initially clear, it is fine-tuned with a fine parifocal spiral to obtain clarity.
​Observation and recording: After finding the observation object with a low power lens, you can gradually change to a high power lens or oil lens for more detailed observation. During the observation process, pay attention to adjusting the brightness of the light source and the aperture size to obtain a better observation effect. At the same time, make observation records for subsequent analysis.
​Matters needing attention
​Light handling: Take and place the microscope action should be light, avoid vibration and violent operation, to prevent damage to the optical components.
​Standard operation: In strict accordance with the operating procedures, the first low magnification and then high magnification, avoiding the direct use of high magnification mirrors to find the target, in order to reduce the wear of the microscope.
​Lens protection: When observing the specimen of the liquid medicine, it should be covered with a slide or placed in a petri dish to avoid corrosion caused by direct contact of the liquid with the lens. After using the oil mirror, clean the oil stains on the lens in time.
​Regular maintenance: Check and maintain the microscope regularly to keep it clean and dry to extend its service life.
​Safe use: When using the microscope, pay attention to the safety of electricity, to avoid electric shock and other accidents. At the same time, comply with the laboratory rules and regulations to ensure the safety and order of the experiment process.